HERS Testing

For HVAC Contractors & New Solar Homes Program

* Duct pressure testing
* Refrigerant charge verification
* Fan watt draw and cooling coil air-flow
* Change-outs and NEW construction.
* Includes CF-6R paperwork for building depts.
* Residential & Commercial
* Contra Costa, Alameda, Solano, Napa Counties
* Solar system compliance testing for New Solar Homes Program
* Competitive rates
* Fast and reliable service

****** New compliance rules for 2010 ******

3rd Party testing requirements for HVAC systems as of Jan 1, 2010

Alterations/change-outs:

  • Duct sealing and testing: Alternatives to duct sealing have been eliminated. Installing high AFUE or EER/SEER equipment is no longer a substitute. (zones 2, 9 – 16)
  • Temperature measurement access holes must be provided in supply and return plenums. (zones 2, 8 – 15)
  • Refrigerant charge measurement required, TXV verification is no longer an alternative.  NOTE: Refrigerant charge must be verified even when doing only a furnace change-out. (zones 2, 8 – 15)
  • Minimum airflow must be verified, 300 cfm/ton. (zones 2, 8 – 15)
  • Cooling coil airflow verified, 350/ton. (zones 10 – 15)
  • Fan watt draw measurement required (zones 10 – 15)
  • Saturation temp sensors must be provided (zones 10 – 15)
  • Static pressure probe: permanent probe or access holes must be provided in supply plenum (zones 10 – 15)

New construction (including major additions):

Duct sealing and testing and other measures are required unless otherwise indicated on the CF-1R.

****  Leakage targets remain the same: Under 6% for completely new duct systems; under 15% leakage for change-outs. ****